India's Leading Construction Chemicals Manufacturer | GST No. 19AAACH8021M1ZE | +91 033 2449 0835 | +91 033 2449 0839

CONCRETING AID

Home/CONCRETING AID
CONCRETING AID 2018-03-19T11:57:47+00:00

CONCRETING AID

Hind Anti Air pdf1

Category: CONCRETING AID

Anti foaming Agent Manufacturer & supplier in India

USES 

Hind Anti Air is recommended for use in latex and emulsion mortars, water based paints and adhesives made latex or emulsion.

ADVANTAGES

  • 1. Removes entrapped air in concrete and making it durable.
  • 2. Makes concrete/mortars cohesive.
  • 3. Increases the strength of concrete/mortars.

APPLICATION

Hind Anti Air can be directly or diluted with water and added into concrete/mortar mixes, emulsions, water based paints and adhesives. Normally the dosage ranges from 0.1% -0.5% by weight of water.

PROPERTIES 

Aspect Light yellowish Compound
Active Content (% by weight)) 100
Sp. Gravity at 200 C 0.89   0.05
Viscosity 100 cps
Dispersibility Is dispersible in water
Flash point (0 C) 176 (C.O.C)
Ion Non-ionic

SHELF LIFE

24 months from the date of manufacture in unopened condition. Should  be stored in a cool and dry place away from direct sunlight. The content to  be stirred well before use if stored for a longer period of time.

PACKING

Available in 10 Kg, 20 Kg HDPE container or as required.

HANDLING PRECAUTION 

Hind Anti Air is non-toxic and prolonged skin contact should to be avoided. In case of contact with eyes occurs wash with plenty of clean water and seek medical advice.

Hind Bond EBA pdf1

Category: CONCRETING AID

High Strength Epoxy Bonding Compound Manufacturer in India

USES

Hind Bond EBA is used as a bonding agent between old to old concrete, old to new concrete, metal to concrete, glazed bricks, tiles, steel or other structural materials to old sound concrete. It is also used for joint sealing.

ADVANTAGES

Hind Bond EBA   provides a bond of far better strength of concrete itself, and suitable wherever structural bonding of new to existing old concrete is required.

APPLICATION

Surface should be cleaned, dry and free from loose particles, oil, grease or other foreign materials. Deep contaminated concrete should be thoroughly cleaned by wire brush. Mix all the pre-weighed  Pack-A with the pre-weighed Pack-B  and stir thoroughly preferably with a low speed electric drill or paddle mixer for 2-3 minutes.. Apply a thin layer of Hind Bond EBA with brush to the existing surface, working well into the substrate. Place fresh concrete/mortar while it is still ‘tacky’.

In case of using large packs, when the entire mixed quantity cannot be used at a time, contents of Pack A and Pack B is to be mixed in the ratio 2:1 by weight and consumed within 30 minutes.

Conditions of Application/Limitations

Temperature of the Substrate:           250 C (Minimum) / 400 C (Maximum)

Ambient Temperature:                        250 C (Minimum) / 400 C (Maximum)

Humidity of the Substrate:                 On moist surface, the adhesive to be brushed well into the substrate.

Temperature of the material:               The material temperature at the time of application should be between 100 C to 400 C.

PROPERTIES

Aspect (Mixed) Greyish white colored fluid
Mixing Ratio Component A: Component B = 2: 1 by weight
Pot Life 25-30 minutes at 300C (as per EN  ISO 9514)Pot life starts when Pack A & Pack B are mixed. Pot life is reduced at high temperature and longer at low temperature. To get a longer pot life small portion by weight to be mixed and applied.
Open Time 45-50 minutes at 300C (as per EN ISO 9514)
Full Curing time at Ambient Temperature 7 days
Compressive Strength (300 C) 60 N/mm2 in 7 days (as per ASTM C 881)
Flexural Strength (300 C) 30-35 N/mm2 in 10 days (as per IS-9162 -79)
Tensile Strength (300 C) 20 N/mm2 in 14 days (as per ISO 527)
Bond Strength (300 C) 2-3 N/mm2(Substrate–Concrete dry) (as per ASTM C 881)

COVERAGE

Hind Bond EBA will cover at the rate of 0.25-0.50 Kg. per Sq. Mtr. depending upon the surface porosity, texture and working temperature.

SHELF LIFE

18 months from the date of manufacture in unopened condition. Should be stored in a cool and dry place away from direct sunlight.

PACKING

1.2 Kg, 3 Kg, 6 Kg. & 18 Kg Kits. All packs contain pre-measured quantity components of Pack A & Pack B.

HANDLING PRECAUTION

Hind Bond EBA is non-toxic and ingestion is to be avoided. Any splashes to the skin must be washed with organic solvent like Xylene. If contact with eyes occurs, wash well immediately with water and seek medical advice. Rubber hand gloves are to be worn while handling.

While mixing and applying Hind Bond EBA, tools and skin contacts are to be cleaned by organic solvent like Xylene/Toluene/MEK.

Hind Cempox (M) pdf1

Category: CONCRETING AID

THREE COMPONENT EPOXY & CEMENT BASED MORTAR FOR SEALING OF CONCRETE MORTAR & STONE SURFACES

DESCRIPTION

 Hind Cempox (M) is a three component epoxy modified cementitious, thixotropic type, fine textured micro mortar for leveling and finishing of concrete, stone or mortar surfaces.

USES

 Hind Cempox (M) has wide range of uses:

  • 1. Can be applied to new work or damaged concrete in aggressive chemical environments.
  • 2. Used as a pore sealer to rebuild the profile, smoothness and leveling of concrete surfaces.
  • 3. Used to control moisture, suitable for restoration work physical resistance, preserving/restoring passivity and for increasing resistivity. (According to various principle & methods of EN-1504-9)
  • 4. Can be applied over substrates containing high moisture and over green concrete.
  • 5. As a leveling layer over concrete/mortar ranging from 0.5-3.5mm on vertical or horizontal surfaces.
  • 6. Can be used as a moisture barrier (min 2mm thick) allowing epoxy, polyurethane and other solvent based coatings to be applied or floors surfaces which requires dry surface prior to its application.

 ADVANTAGES

  • 1. Excellent adhesion to hardened or green concrete in dry or dampen conditions.
  • 2. Solvent free and Ideal preparation to obtain smooth finish surface.
  • 3. Improves chemical resistance to substrates.
  • 4. Protects concrete in aggressive environments.
  • 5. Impermeable to liquids but preamble to water vapours.
  • 6. Can be used for both in external and internal use.
  • 7. Outstanding resistance to water and moisture.Application Temperature The material has to be kept at temperature ranging between 100C to 300C. It has to be ensured that the substrate temperature is maintained in between 100C to 300C. The Relative humidity should be between 200C to 800C.Curing  Full cured ~ 4 days at  +300C. PROPERTIES 
    Form  Epoxy  Modified Cementitious Mortar
    Aspect Component A (Resin)      :      Transparent liquidComponent B (Hardener):     Transparent yellow liquid

    Component C  (Filler)      :      Grey Aggregate powder

    Mixing Ratio Component A (Resin) : Component B(Hardener) : Component C (Filler) :: 4:1:18
    Pot Life  at 270 C 30min
    Over Coating Time at 270 C 8hr
    Density at 270 C Component A (Resin)          1.140kg/lComponent B (Hardener)   1.070kg/l

     Component C  (Filler)         1.300kg/l

    Mixed (A+B+C)                    1.900kg/l

    Compressive Strength (28 days) > 45 N/mm2
    Flexural Strength (28 days) > 5N/mm2
    Chloride Content (EN1015-17) <  0.05%
    Sulphate Resistance High Sulphate Resistance
    Modulus of Elasticity ~ 17 GPa
    Coefficient of Thermal Expansion ~ 13.0 µm/m 0C
    Coefficient of Carbon Dioxide Diffusion µCO2   ~ 5400
    Capillary Absorption (Water permeability) <  0.5Kg. m-2 . h -0.5
    Adhesive bond >2.0 MPa
    Restrained Shrinkage/Expansion >2.0 MPa
    Capillary absorption & permeability to water <  0.1Kg. m-2 . h -0.5
    Abrasion Resistance (Taber Test)(EN ISO 5470-1) Weight loss < 3000mg  H22 rotation, 1000 cycles/load  1000g
    Permeability to water vapour Class 1 : SD <5 m (permeable to water vapour)
    Impact Resistance (EN ISO 6272-1)
    Adhesion strength by pull-off test (EN1542) >2.0 N/mm2 (horizontal with trafficking)
    Durability Carbonation resistance(EN 13295) Pass

     

    Coverage/Consumption :  Coverage as Screed/Mortar/ Rendering  ~ 2.0Kg/m2/mm . The coverage is depended on the surface porosity, profile , level variations and wastages.

    Quality of Substrate

     

    The concrete substrate should be sound and hard (M-25 grade) with a minimum compressive strength of 25N/mm2  and a pull off strength of 1.5 N/mm2

    Surface Preparation

     

    Concrete surfaces

     

    It should be ensured that concrete has attained the design strength and is properly cured. Concrete surfaces should be mechanically prepared or water jetted with high pressure equipment to remove cement laitance, oil and grease con­­tamination if present and obtain a clean dust free surface. Weak concrete to be totally removed and blow holes/voids on the surface if any to be exposed completely. Repair of blow holes/voids  and surface leveling to be obtained using Hind Patch R.  High level spots to be properly grinded.

    Priming

    Prior to application of Hind Cempox (M) the concrete surface to be pre-wetted with water and should not be allowed to become dry. The surface should not have water accumulation and should be in Surface Saturated Dry (SSD) condition.

    All type of Surfaces like Green Concrete (as soon as it is suitable for mechanical preparation), Concrete substrate more than 14 days old and Damp old aged concrete with rising moisture is suitable for priming.

     

    Mixing

    Before  mixing Component A (Resin) to be shaken properly and then poured into the container  of Component B (Hardener) and shaken vigorously  for minimum 30 seconds.  To the mixed binder (A+B) now Component C (Filler) is added gradually  and stirred with a slow speed power mixer (300- 400 RPM) for 3- 4 minutes to achieve a homogenous mix with any lumps. Mix pre-weighted Component (A+B+C) full quantity. Water should not be added.

    APPLICATION

     

    Hand Application

    The mixed Hind Cempox (M) is applied on the damp surface and is spread over with a trowel/spatula to obtain the required thickness. If necessary it can be finished with a moist neoprene made sponge or brush.

    Mechanical Application

    It can also be sprayed to the surface by using a spray gun or by wet spray techniques. After spraying operation is over it is to be subsequently finished by hand. Additional water is not to be used which may cause improper surface finish.

    New & fresh applied surface with Hind Cempox (M) must be protected from rain for the first 24 hours from the time of application. When the surface of Hind Cempox (M) becomes tack free vapour permeable sealing coatings can be applied. The surface moisture to be checked which  should be less than < 4% before application of vapour tight coatings. Seamless finish is achieved if a wet edge is maintained during application.

    SHELF LIFE

    Component A & Component B -12 months, Component C – 6 months,  from the date of manufacturing in unopened conditions. To be stored in a cool and dry place away from direct sunlight.

    PACKING

    23Kg Kit. (Comp A – 4Kg, Comp B – 1 Kg & Comp. C-18Kg)

    HANDLING PRECAUTION

     Hind Hind Cempox (M) is non-toxic and ingestion is to be avoided.  If contact with skin, eyes occurs wash well immediately with water and seek medical advice.

Hind Corroguard pdf1

Category: CONCRETING AID

Corrosion inhibitor for reinforced concrete

PERFORMANCE 

Hind Corroguard functions as a high performance corrosion inhibiting admixture simultaneously affects both anodic and cathodic processes, it contains molecules in which electron density distribution causes the inhibitor to be attracted to both anodic and cathodic sites. By virtue of the moisture within the concrete these molecules migrate towards the steel and get deposited in a monomolecular layer along the steel and reestablish the barrier between the steel and chlorides to prevent corrosion.

USES

Hind Corroguard should be added directly to the concrete at the batching plant or transit mixture.

DOSAGE

The optimum dosage of HIND CORROGUARD to meet specific requirements should always be determined depending on the severity of the corrosion environment and anticipated chloride loading of the structure. Normally we recommend dosage range in between 2-3Kg per M3 of concrete.

PROPERTIES 

Aspect Pale yellow Liquid.
Active Ingredients 100% Organic compound
Specific Gravity 1.05 – 1.08 at 25°C
Viscosity at 25°C 11-12 secs by Ford B4 Cup
pH Minimum 9.0
Toxcity Non-toxic, Echo-friendly.
Effect No adverse effect on the physical properties of fresh & hardened concrete.

SHELF LIFE 

In un-opened condition, protected from direct sunlight and frost at temperatures between 5ºC and 50°C,   Shelf Life is 12 months from the date of manufacture. It should be stored away from reducing agents and combustible materials.

PACKING

225 Kg. Container or as required. 

HANDLING PRECAUTION

Hind Corroguard is non-toxic and ingestion is to be avoided.  Any splashes to the skin must be washed with water. If contact with eyes occurs, wash well immediately with water and seek medical advice.

Hind Corroguard SA pdf1

Category: CONCRETING AID

Corrosion inhibitor paint for concrete – Corrosion inhibitor for Coating

PERFORMANCE 

Hind Corroguard- SA functions as a high performance corrosion inhibiting admixture simultaneously affects both anodic and cathodic processes, it contains molecules in which electron density distribution causes the inhibitor to be attracted to both anodic and cathodic sites. By virtue of the moisture within the concrete these molecules migrate towards the steel and get deposited in a monomolecular layer along the steel and re-establish the barrier between the steel and chloride to prevent corrosion.

USES 

Hind Corroguard-SA should be applied over thoroughly cleaned concrete surface free from any types of existing paints, oil, or grease.

DOSAGE

The optimum dosage of Hind Corroguard-SA to meet specific requirements should always be determined depending on the severity of the corrosion environment and anticipated chloride loading of the structure. Normally we recommend dosage/coverage ranging between 4-5 Sq. Mtr. per Kg per Coat over concrete.

PROPERTIES 

Aspect Pale yellow Liquid.
Active Ingredients 100% Organic compound
Specific Gravity 1.05 – 1.08 at 25°C
Viscosity at 25°C 11-12 secs by Ford B4 Cup
pH Minimum 9.5
Toxcity Non-toxic, Echo-friendly.
Effect No adverse effect on the physical properties of fresh & hardened concrete. It does not entrain air.

 SHELF LIFE

In un-opened condition, protected from direct sunlight and frost at temperatures between 5ºC and 50°C,   Shelf Life is 12 months from the date of manufacture. It should be stored away from reducing agents and combustible materials.

PACKING

225 Kg. Container or as required.

HANDLING PRECAUTION 

Hind Corroguard-SA is non-toxic and ingestion is to be avoided.  Any splashes to the skin must be washed with water. If contact with eyes occurs, wash well immediately with water and seek medical advice.

Hind Cure AL pdf1

Category: CONCRETING AID

USES 

Hind Cure AL is sprayed or brushed into newly laid concrete surfaces to form a thin barrier against premature water loss. Without hindrance to the normal curing phenomenon due to adequate hydration water held by the concrete matrix underneath and for negligible evaporation of water from below resin membrane the concrete achieves maximum beneficial properties.

ADVANTAGES 

Hind Cure AL is very useful in large areas of exposed concrete such as

  • 1. Concrete Highways-Road construction.
  • 2. Air Port
  • 3. Apron and hard standing.
  • 4. Roof decks and shell-roofs.
  • 5. Retaining walls.
  • 6. Pre stressed beams and piers.
  • 7. Canal lining.
  • 8. Exposed surfaces of dams.
  • 9. Sloping and angular surface where pond curing is not possible.

APPLICATION 

Hind Cure AL curing compound is recommended for application once the surface water has disappeared. As it is solvent based, the equipment are to be cleared with mineral Solvents, such as white spirit, kerosene oil, etc. soon after completion of job. It is recommended to stir the contents of container before application and to keep the product away from flame and heat under shade. Application can be done by spray or brush. The coverage depends on site condition such as wind velocity, temperature and humidity.

PROPERTIES 

Aspect Aluminum Pigmented Liquid
Colour Silver Grey
Specific Gravity 0.82 ± 0.02 at 27° C
Non-volatile solid content 19 ± 2%
Coverage 6 to 7 Sq. metre/Litre

It dries like pigmented lacquer when sprayed/brushed into newly laid concrete surface not containing surface water. The evaporation rate of water from under the membrane film is as low as 0.30 Kg against 0.55 Kg (Maximum) per Sq.Mtr. per 24 hours stipulated in ASTM/BS/MOST (GOVERNMENT OF INDIA) specification.

SHELF LIFE 

12 months from the date of manufacture in unopened condition. Container should be protected from sunlight and naked flame

PACKING 

100, 200 Litre. in HDPE container or as required

HANDLING PRECAUTION 

Hind Cure-AL is non-toxic but ingestion is to avoided. Any splashes to the skin must be washed with water. If contact with eyes occurs, wash well immediately with water and seek medical advice.

Hind Cure SS pdf1

Category: CONCRETING AID

SODIUM SILICATE BASED CURING, HARDENING AND SEALING COMPOUND

 DESCRIPTION

 Hind Cure SS  is a sodium silicate based multipurpose compound  when applied  on  concrete surface it cures, hardens and seal the concrete. It reacts with the cement chemically and penetrates deeply to solidify all ingredients to form a homogenous mass.  The solidification leads to hardened surface, hence surface cracks and spalling is restricted. It is used on all new concrete surfaces and conforms to ASTM  C309-81.

 USES

Hind Cure SS  is sprayed or brushed into newly laid concrete surfaces, which seals the concrete surface and resist premature water loss from within concrete, without creating any hindrance to the normal curing phenomenon due to adequate hydration, water held by the concrete matrix and for very slow evaporation rate of water from below the surface, concrete achieves maximum beneficial properties.

ADVANTAGES

  • Single component, ready to use.
  • It penetrates deep into the surface, densify and hardens the concrete which does not allow entry of moisture or any other foreign matter.
  • Scratch and peel proof.
  • Chemical and Oil resistant and surface becomes abrasion resistant on its application.
  • It is cost effective due to high coverage.
  • Surface becomes crack resistant on its application.
  • It can be used with wax based curing compounds.

APPLICATION

 Before application the concrete surface should be clean, dry and there should be no standing water on the surface. It must also be ensured the surface should be properly cleaned if any coating of sealer or other material exists which will prevent the absorption of the compound.

After proper stirring/agitating the compound in the container, it is applied as a continuous coating to form a film on the concrete surface by brush, power operated sprayer, soft bristle broom or squeegee. It is recommended to recoat the surface if porous and penetration even takes place after application of the first coat.  It makes the surface abrasion resistant. Excess material which gets sagged should be removed immediately from the surface.

PROPERTIES

Aspect Milky White Liquid
Specific gravity 1.24 + 0.05 at 270 C.
Coverage

Fresh  Concrete Surface

8-10 Sq. Mtr /Kg depending on the porosity and texture of the substrate.

 APPLICATION TEMPERATURE

 Hind Cure SS is recommended to be applied when the temperature of substrate should not be less than 50 C and higher than 500 C.

  SHELF LIFE

12 months from the date of manufacture in unopened condition.  To be stored in a cool and dry place away from direct sunlight.  It should not be allowed to freeze.

PACKING

20 Kg  & 250 Kg Container.

HANDLING PRECAUTIONS

 Hind Cure SS is non-toxic, non-combustible and inhalation to be avoided. Any splashes to skin if happens, wash with water. If contact with eyes occurs, immediately wash with water and seek medical advice.

Hind Cure WP pdf1

Category: CONCRETING AID

USES

Hind Cure WP is sprayed or brushed into newly laid concrete surfaces to form a thin film barrier against premature water loss, without hindrance to the normal curing phenomenon due to adequate hydration, water held by the concrete matrix and for very slow evaporation of water from below the membrane so that concrete achieves maximum beneficial properties.

ADVANTAGE 

Hind Cure WP is very useful in large areas of exposed concrete such as

  • 1. Concrete Highways-Road construction.
  • 2. Air Port
  • 3. Apron and hard standing.
  • 4. Roof decks and shell-roofs.
  • 5. Retaining walls.
  • 6. Pre stressed beams and peers.
  • 7. Canal lining.
  • 8. Exposed surfaces of dams.
  • 9. Sloping and angular surface where pond curing is not possible.

APPLICATION 

Hind Cure WP curing membrane is recommended for application to the newly laid concrete once the surface water has disappeared. For large areas of concrete such as concrete Highway. Power driven automatic spray equipment attached to paver machine is employed. The contents are to be stirred well before application as in Paints application.

PROPERTIES 

Aspect White Liquid
Specific Gravity 0.9 ± 0.05 at 27° C
Coverage* 5 to 6 Sq. Metre/Litre.

* Coverage depends on site condition such as wind velocity, temperature, humidity and porosity of the surface.

Hind Cure WP compiles with ASTM C-309-81 type 2, class A, ASTM C 156, ASTM E 97 and BS: 7542 specification in respect of rate of evaporation loss. The weight of water lost per square meter of coated concrete surface in 24 hours is 0.40 kg. against 0.55 kg. (Maximum) stipulated in Ministry of Surface Transport (Most) Govt. of India’s specification.

SHELF LIFE 

12 months from the date of manufacture. Container should be protected from direct sunlight.

PACKING 

100, 200 Litre HDPE container or as required.

HANDLING PRECAUTION 

Hind Cure WP is non-toxic but ingestion is to avoided. Any splashes to the skin must be washed with water. If contact with eyes occurs, wash well immediately with water and seek medical advice.

Hind Fiber Glass pdf1

Category: CONCRETING AID

USES

Hind Fiber Glass when used as reinforcement for protective and waterproofing coating it provides high strength and is impact resistance. It is used for reinforcing cement, stone, epoxies, bitumen, gypsum, wall material, roofing etc.

ADVANTAGES

  • 1. Eliminates surface cracking of protective and waterproofing coatings.
  • 2. Water Resistant & Alkali Resistant.
  • 3. Soft and flexible for easy application.
  • 4. Resistant to ageing.
  • 5. Usable on a wide range of surfaces.

APPLICATION

All surfaces should be sound, clean and free from any contamination like grease, oil, loose particles etc. After the base coat is applied Hind Fiber Glass is to be laid and embedded properly, when the coating is still green. It is to be ensured that there are no wrinkles, and the fabric is continuous at all corners and properly lapped and butted lapping and before application, the surface and tiles should be pre wetted properly. The base coat should have minimum thickness so that the fabric is uniformly embedded over the entire surface.

PROPERTIES

Weight 45 gram per M2
Mesh Size 2.5mm X 2.5mm
Width 1000 mm

PACKING

Available in 100/50 Meter Roll

HANDLING PRECAUTION

Hind Fiber Glass is non-toxic, suitable for all surfaces even in contact with potable water.

Hind Foamex pdf1

Category: CONCRETING AID

Foaming agent for concrete and mortar

USES

Hind Foamex is recommended for use in structures that is required to be thermally insulated and protected against the ingress of moisture, like Roof / Terrace, Basements, Masonry AC Ducts, Cold Storages, Auditorium, Hospital, Industrial Factory Shades etc.

ADVANTAGES 

  • 1. Provides full proof thermal insulation, saving energy.
  • 2. Low permeability makes mortar or concrete waterproof.
  • 3. Imparts chemical resistance to substrate.
  • 4. Reduces or prevents salt penetration into concrete
  • 5. Due to light weight does not add extra load to roof structure.
  • 6. It has a good mechanical stability & acts as a excellent shock absorber.

APPLICATION

To the freshly prepared cement Slurry maintaining W/C ratio 0.6, Hind Foamex is added and mixed with a high speed mixer to generate foam concrete. To get the desired density of the foam concrete, light weight additives like vermiculite or perlite may be used. It also reduces the cement consumption for making cement slurry. It is recommended to mix Hind Foamex with water used for making cement slurry to achieve best results. Normally curing is to be carried on for 7 (seven) days. Foam concrete blocks can be used for non-load bearing partition walls in multi storied buildings as per required dimensions. To minimize the water absorption of the foam concrete, the surface may be coated/sprayed with Hind Coat Repel, silicon based water repellent coating. To achieve full proof waterproofing of roof, Hind Crete Plus WPM admixed with cement in the ratio of 1:2 in two coats to be applied over the roof surface, prior to foam concreting.

TYPICAL DENSITY RECOMMENDATION

CLASSIFCATION DENSITY  
Thermal Insulation/Fire Protection 250-550 Kg/m3
Void Filling 600-800 Kg/m3
Production of blocks for use in non-load bearing partition walls 800-900 Kg/m3
Prefabricated /Cast in place walls both load and non load bearing 1100-1400 Kg/m3
Slabs & higher strength loading bearing building elements 1600-1800 Kg/m3

PROPERTIES 

  Aspect Pale Orange Liquid
  Specific Gravity at 27ºC 1.04  ±  0.05
  pH 11  ±  2
Solubility Miscible with water in all porportions
Chloride 0.2%  Max  (considered to be Nil)
Dosage of Foaming Agent(Normal Dry Density 750 Kg/m3 ) 1.25 to 1.60 Kg  diluted with 25-40 parts water

SHELF LIFE

12 months from the date of manufacture in unopened condition. Should be stored in a cool and dry place away from direct sunlight.

PACKING

20 Kg & 250 Kg Barrel.

HANDLING PRECAUTION 

Hind Foamex  is non-toxic and prolonged skin contact should to be avoided. In case of contact with eyes occurs wash with plenty of clean water and seek medical advice. Cleaning of tools is to be done with water.

Hind Mould Release OB pdf1

Category: CONCRETING AID

Oil Based Shutter Release Agent Manufacturer in India

USES 

HIND Mould Release OB can be used:

  • 1. To Provide quick, clean and easy stripping of moulds or form work.
  • 2. To obtain clean and smooth concrete surface.
  • 3. To protect steel and wooden form work.

ADVANTAGES

  • 1. Minimum cleaning of shutters before re-use.
  • 2. Extended life of form work.
  • 3. Can be used on all types of form work.
  • 4. Improved finish, stain and air free fair faced concrete.
  • 5. High coverage.
  • 6. Non corrosive to steel.
  • 7. Dust free concrete surface.

APPLICATION 

Apply one coat only by brush, roller or spray on the clean surface. Hind Mould Release OB after application should be allowed to dry before concreting takes place.

PROPERTIES 

Aspect Light brownish/ Light greenish liquid
Coverage 20 to 50 Sq. mtr. /LitreThe consumption depends on the surface texture and porosity of the form work.

SHELF LIFE

12 months from the date of manufacture. Container should be protected from sunlight and naked flame.

PACKING 

100, 200 Ltr. Container

HANDLING PRECAUTION

Hind Mould Release OB is non-toxic but ingestion is to be avoided. Any splashes to the skin must be washed with water. If contact with eyes occurs, wash well immediately with water and seek medical advice.

Hind Mould Release WT pdf1

Category: CONCRETING AID

Water Based Shutter Release Agent

USES

  • 1. To Provide quick, clean and easy stripping of moulds or form work.
  • 2. To obtain clean and smooth concrete surface.
  • 3. To protect steel and wooden form work.

ADVANTAGES

  • 1. Requires only water for use.
  • 2. Minimum cleaning of shutters before re-use.
  • 3. Extended life of form work.
  • 4. Can be used on all types of form work.
  • 5. Improved finish: stain and air free fair faced concrete.
  • 6. Non corrosive to steel.
  • 7. Dirt-free concrete surface.

APPLICATION 

Apply one coat only by brush, roller or spray on the clean surface. Hind Mould Release WT after application should be allowed to dry before concreting takes place.

PROPERTIES 

Aspect Light brown liquid
Coverage(After dilution) 30 to 40 Sq. mtr /Litre (Wood)
Dilution Rate- Hind Mould Release WT : Water = 1:6 40 to 50Sq. mtr /Litre (Steel or plastic)

 SHELF LIFE 

12 months from the date of manufacture in unopened condition. Container should be protected from sunlight and naked flame

PACKING 

100, 200 Litre, HDPE container or as required.

HANDLING PRECAUTIONS

Hind Mould Release WT is non-toxic and ingestion to be avoided. Any splashes to the skin must be washed with water. If contact with eyes occurs, wash well immediately with water and seek medical advice.

Hind Patch R pdf1

Category: CONCRETING AID

USES 

It is used for  repairing of  reinforced concrete elements protecting it from sulphate and chloride attack. Can be used to repair underground and marine concrete structures. It is used for smoothening of concrete surface prior to application of waterproofing polymer coatings.  High strength concrete elements can also be repaired with Hind Patch R. It is an ideal mortar for repairing of tie-rod holes used for fixing of shuttering.

ADVANTAGES

  • 1. Easy to use only water to be added and applied.
  • 2. Excellent bonding to concrete & steel.
  • 3. Non-sagging/thixotropic properties make it an ideal compound for overhead applications.
  • 4. Non -Shrink.
  • 5. High strength and waterproof.
  • 6. It high resistant to oils, sulphate and chloride attacks and freeze-thaw cycle. 

APPLICATION 

Substrate Preparation

The concrete surface to be properly cleaned and it should be sound and dry. It should be free of frost, curing compound membrane, waterproofing treatments, oil, laitance, other containments and dust. The area to be repaired should be free from all loose particles and properly saw-cut perpendicular to the repair surface. Worn out corroded reinforcement to be replaced with new ones and cleaned properly. The surface to be pre-wetted before application of Hind Patch R.

Mixing 

Adequate quantity of clean water is taken in a container and properly gauged. Hind Patch R is added into the water slowly and continuously mixed with a electrical mixer (400-600rpm) fitted with a paddler for 4-5 minutes, so that an uniform homogenous mix is obtained. The mix is allowed to rest for 3 minutes so that entrained air escapes out and finally remixed for another 30-40 seconds.

Mixing Ratio: Mix 1 Kg Hind Patch R with 150-155 ml of water.

Method of Application

Hind Patch R is now applied on the prepared surface with a steel trowel and that thickness of the mortar should be between 1- 4 cm.  If the application of the mortar is required to be thicker than further layer is applied by the same process after 24 hours .  When the mortar sets initially water is sprinkled on it and is finished with a steel/ wooden trowel.  Open area applications are to be protected from rain and severe weathering conditions for the first 24-48 hours from the time when repairing gets finished with wet cloth or curing compounds.

Coverage

19.15 to 19.25 Kg/m2   to obtain a thickness layer of 1cm.

Cleaning of Tools  –  Clean all tools with water. Avoid hardening of the materials otherwise to be cleaned by mechanical abrasion.

PROPERTIES 

Aspect Grey Powder
Mixed Density (W/P Ratio ::  0.155 : 1) ~ 2.25 Kg/litre
Pot Life 30 minutes
Compressive Strength 19-20 N/mmafter 1 day
> 50 N/mm2    after 7 days
> 60 N/mm2   after 28 days
Flexural Strength 6-7 N/mm2    after 28 days
Bond Strength to Concrete > 2 N/mm2   after 28 days
Modulus of Elasticity > 20,000 N/mm2   after 28 days
Capillary Water Absorption < 0.5 Kg.m-2.hour-0.5
Thickness of application 10mm (Min.)   40mm (Max.)
Application Temperature 50 C to 400 C
Full Curing at 230 C 28 days

Note:   Higher temperature shortens the curing & working time , lower temperature extends the durations. Ideal Temperature is 23C and 500 C  Relative Humidity.

SHELF LIFE

12 months from the date of manufacture in unpacked condition. Should be stored in a cool and dry place.

PACKING

Available in 25 Kg. HDPE Bag

HANDLING PRECAUTION 

Hind Patch R is non-toxic and ingestion is to be avoided. If contact with eyes occurs, wash well immediately with water and seek medical advice.

Hind PP Fiber pdf1

Category: CONCRETING AID

USES

Hind PP Fiber when incorporated into concrete or mortar, it effectively prevents temperature variations, micro-cracks occurring due to plastic and dry shrinkage etc. It also adds to prevention and control of crack development and improves effectively anti-cracking, anti-infiltration, anti-concussion and makes the concrete shockproof. It has its uses in PCC, RCC, Plastering, Shotcreting, Guiniting, Slabs, Foundations, Walls, Tanks, Pre-stressed Beams, Pipes, Concrete blocks, Railway Slippers, Roads, Pavements, Bridges and Dams.

ADVANTAGES

  • 1. Reduces water permeability- making the concrete impervious and resulting to prevention of corrosion of the reinforcement in concrete.
  • 2. Reduces Rebound Loss in concreting process, hence directly bringing down the cost of raw materials.
  • 3. Durability of concrete/mortars is enhanced.
  • 4. Very good biological resistance
  • 5. Easy to use and easily dispersible in both aqueous and non-aqueous medium.
  • 6. No agglomeration and easily spreadable in concrete & mortar thus improving the mechanical strength                and reducing cracks.
  • 7. Due to very thin fibers it gets spread evenly in mortar and improves the binding properties of the plaster between surface and substrate.
  • 8. Possess stable chemical properties, strong acid & alkali resistant and is recommended in all types of               constructional activities.
  • 9. Environmental friendly and non hazardous.

APPLICATION

Hind PP Fiber should be directly added to dry material and mixed for about a minute prior to addition of water. Dosage varies from 0.6-1.5 Kg/m3 of the volume of the total cementitious material.

PROPERTIES

Identical Diameter (m) 35±5µm
Density (g/cm3) 0.91~0.93 g/cm3
Length (mm) 6, 12, 15, 19 ± 1 mm
Modulus of Elasticity (mpa) ≥3500 mpa
Tensile Strength (mpa) ≥500 mpa
Elongation at Break (%) ≥ 15%
Melting Point (0C) 160~1800C

PACKING

Available in 0.9 Kg & 18 Kg Bag.

SHELF LIFE

Three (3) years from the date of manufacture, provided the material is stored in a perfectly dry place and in unopened conditions away from direct heat and sunlight.

HANDLING PRECAUTION

Hind PP Fiber is non-toxic and ingestion is to be avoided. Contact with eyes or skin causes irritation and must be avoided. It should not be stored near flame. Use of Hand gloves is recommended.

Hind Pump Prime pdf1

Category: CONCRETING AID

  

USES

Hind Pump Prime is used as a most effective priming compound and as a pumping aid for concrete pump. It is used very effectively when concrete is pumped through long distance pipelines from the batching plant to the pouring point. The phenomenon of friction when the concrete passes through long pipelines get reduced and the lubrication effect of the compound makes concrete pass smoothly without any choking of the pump and pipeline. In the construction of Bridge Piers, Decks, Dams, Tunnel, Shafts, Well-foundation, etc., where there is huge volume of concreting involved, use of this unique compound eases out choking problems of concrete pumps.

ADVANTAGES 

  • 1. Use of the compound reduces the friction force developed in the pipeline when concrete is pumped.
  • 2. It acts as a lubricant on the wall of the pipeline allowing harsh mix to pass smoothly.
  • 3. Reduces the risk of choking when concrete is placed by pump at higher temperature.
  • 4. Efficiency of the concrete pump gets increased.
  • 5. Cost effective and resists the wearing of pipeline.
  • 6. Ready to use only water to be added.

DIRECTION FOR USE 

For Priming of Concrete Pump:

Hind Pump Prime when used for priming of Concrete pump, the entire pouch of 250 gm,  is to be poured at one side of the pump hopper or separately in the bucket where the slurry is being made. About to 20 to23 Ltr. of water is to be added to it and stirred uniformly for complete dissolution of the same. The slurry produced from one pouch will be sufficient for priming 70-80 meters length of pipeline. For a pipeline length of 120 meters, 2(two) number pouches are to be used. Whenever additional pouches are used for priming of increased pipeline length, it is to be always ensured that extra water of 20-23 Ltr. is added for proper dissolving of the powder and for better performance.

As a Pumping Aid for Stiff Mixes

Hind Pump Prime when used as a pumping aid for pumping stiff mixes, one pouch (250 gm) is recommended to be used for 1- 5 cubic meter of concrete. The content of the pouch is mixed directly into concrete produced either by Mixture Machine or in Batching Plant and is made to be mixed for 5-6 minutes uniformly with the concrete. It is always advised to perform prior test and determine the suitability of Hind Pump Prime in concrete, because it absorbs water for hydration and this may have an adverse effect on concrete produced with Superplasticiser at low W/C ratio. 

PROPERTIES 

Aspect White Powder
Dosage a) When used for priming of pump, a 250 gm. Pouch pack is to be added to 20 to 23 Ltr of water, producing slurry of desired consistency for priming 70-80 meter length of pipeline.

b) When used as a pumping aid for stiff mixes, a 250 gm. Pouch pack is to be added to 1-5 cubic meter of concrete. It is always recommended for doing prior testing of the same before adding to concrete to get desired result in terms of workability and strength

Chloride Content Nil – As per B.S – 5075 (Part – 1)

 SHELF LIFE

12 months from the date of manufacturing in unopened conditions. To be stored in a cool and dry place away from direct sunlight. 

PACKING

Available in 250 gms.  Plastic pouch pack.

HANDLING PRECAUTION 

Hind Pump Prime is non-toxic but ingestion is to avoided. If contact with eyes occurs, wash well immediately with water and seek medical advice.

Check product demo on 

 

Hind SBR Bond pdf1

Category: CONCRETING AID/u>

USES

Hind SBR Bond has wide range of uses, for bonding of old concrete with new concrete, such as interior surfaces, floors , roadways, bridge decks, ramps , runway, walkways and curbs. It is also used for repairing of spalled concrete, damaged floors/slabs and when added to cement mortar provides a water proof plaster surface.

ADVANTAGES 

  • 1. Improves bond to mother substrates.
  • 2. Excellent adhesion to a wide range of substrates.
  • 3. Improves flexibility of the treated area.
  • 4. Improves mechanical properties and abrasion resistance.
  • 5. Improves chemical resistance to substrates.
  • 6. Low permeability makes mortars/concrete waterproof.
  • 7. Improves workability and adhesion of mortars.
  • 8. Strength remains unaffected.
  • 9. Prevents finished surfaces from cracking.
  • 10. Outstanding resistance to water and moisture.

APPLICATION 

Surface preparation: The substrate must be structurally sound, clear and dust free, oil, grease and contaminants must be removed mechanically. Smooth surface must be scrubbed. Surface should be damped with water prior to application of the bonding primer, modified mortar or concrete. All excess water should be removed from the surface.

PROPERTIES 

Aspect Milky white
pH 7-9
Sp. Gravity 1.02 ±  0.01
Base SBR (Styrene butadiene rubber)
Form Liquid.

APPLICATION & RECOMMENDED CONSUMPTION 

Ingredients Bonding Coat /Waterproof coating Polymer Mortar forPlastering
Cement 3 to 3.5 parts by weight 10 parts by weight
Zone II Sand Nil 40 parts by weight
10 mm nominal sizeCoarse Aggregates Nil Nil
Water 1 part by weight 4 parts by weight
Hind SBR Bond 1 part by weight 1 part by weight
Hind SBR Bond :Water : Cement 1:1 : 3 1:04:10
Coverage 0.250 to 0.50 Kg/Sqm/coat 0.45 to 0.50 Kg/Sq.m/10 mm thickness

SHELF LIFE 

12 months from the date of manufacturing in unopened conditions. To be stored in a cool and dry place away from direct sunlight.

PACKING

1 Kg. 5 Kg. and 20 Kg. Plastic Containers

HANDLING PRECAUTION 

Hind SBR Bond is non-toxic, non-flammable and ingestion is to be avoided. Any splashes to the skin must be washed with water. If contact with eyes occurs, wash well immediately with water and seek medical advice.

Hind Silica M pdf1

Category: CONCRETING AID

MICROSILICA IN POWDER FORM FOR CONSTRUCTION

 DESCRIPTION

 Hind Silica M is a dry fine particles of silica fume, in a compacted dry powder form of mineral origin. The specific surface area of  Hind Silica M is very high, as a result of which it fills up minute voids in the cement-sand matrix. It is also a supplementary cementitious binder, because it vigorously promotes secondary hydration reaction to form further C-S-H gel. The material conforms to IS 15388 – 2003 & ASTMC – 1240

 USES

 Hind Silica M is used in production of high grade, high strength concrete. Its use makes concrete impervious and enhances durability. It is used for construction of basements, railway platforms, marine structures, kerbs, highway dividers, pavements, Bridges, Dams, Tunnels, Water-retaining walls, PSC girders, bridge decks and concrete structures with long spans. mass concrete work keeping the cement content less. To improve the workability and flow of concrete admixed with Hind Silca M, a suitable superplasticiser or an air-entraining agent like ‘Hind Plast Super SCA/Hind Plast AEA’ may be used in conjunction.

ADVANTAGES

 

  • 1. Improves flexural and bond strength.
  • 2. Highly enhances durability.
  • 3. Solid resistance to chemical attacks.
  • 4. Creates dense, compact impermeable concrete.
  • 5. Resists freeze/thaw effect.

 APPLICATION

The application procedure and dosage are entirely dependent on the site requirements. The best possible dosage is possible to be ascertained on the basis of site trials. As a guideline 3% to 5% by weight of cement is used in concrete without any cement replacement. For high grade concrete 10% to 15% may be used as replacement of cement to enhance durability and achieve high strength. However, trials should be conducted to fix the exact dose.

 PROPERTIES

Aspect Grey fine Powder
SiO2 Content (%)                                             (IS:1727- 1967) > 85
Moisture (%)                                                   (IS:15388-2003) < 3
Loss on Ignition (LOI %)                               (ASTM C 1240) <6
Bulk Density (Kg/m3 ) densified >550
Alkalis as equivalent to Na2 O (%)                  (IS:4032 – 1985) <1.5
Specific Surface (BET – M2 /gram) >15
Fineness Retained on 45 micron sieve (%)     ( IS:1727- 1967) <10
Variation from average retained on 45 micron sieve (%) <5
Specific Gravity 2.20 + 0.05

 SHELF LIFE

 18 month in factory packed condition. Store in a dry and cool covered place away from direct sunlight.

PACKING

20 Kg. in HDPE Bag.

HANDLING PRECAUTION

 

Hind Silica M is non-toxic and ingestion is to be avoided.  If contact with skins or eyes occurs, immediately wash with water and seek medical advice.

Hindcon Chemicals – Microsilica Supplier in India

Hind Super Cure R pdf1

Category: CONCRETING AID

USES 

Hind Super Cure R is used as a most effective, economical sealing/priming compound and also as a protective coating which can be applied on all types of concrete surfaces. It is very effective to surfaces which is subject to finishing treatment, economical enhancement of large concrete flatwork and is very cost effective for high rise building construction which requires protection of the structure from carbonation attack and water required for curing.

ADVANTAGES 

Hind Super Cure R is very useful in large areas of exposed concrete such as

  • 1. Retention of moisture in concrete is improved.
  • 2. Rapid water evaporation from concrete is prevented.
  • 3. Reduces shrinkage cracks.
  • 4. Effectively used in Marine environment to overcome corrosion.
  • 5. It is UV resistant and allows the concrete to breathe.
  • 6. Acts as a sealer and dust-proofer.
  • 7. Good abrasion resistant property.
  • 8. Non –biodegradable and does not required to be removed for surface finishing.
  • 9. Acts as a base/primer coat for application of protective coating and bitumen.
  • 10. Has a very high curing efficiency.

APPLICATION 

Hind Super Cure R is a protective membrane forming compound and is recommended for application to the newly laid concrete once the surface water has disappeared. For large areas of concrete such as concrete highway, power driven automatic spray equipment attached to paver machine is employed. The content is to be stirred well before application as applied for paint application. For application over floor it should be applied by brush or spray which will seal all the pores making the floor dust proof. Recommended temperature of the surface should not increase 400 C at the time of application

PROPERTIES 

Aspect White or Light Brown Liquid
Specific Gravity White – 1.02   0.01 at 250 CLight Brown – 0.98   0.01 at 250 C
Dry Surface Finish Appearance White or Transparent
Flash Point 300 C
Dry Film Thickness 100 microns
Full cure/Drying Time( ASTM C 309) 40 mins at 250 C
Loss of Water (ASTM C 156) < 0.55 Kg/m2   in 72 hours

Compliance Standards: 

Clear Version    :  ASTMC 309 Type 1, Class B

White Version   :  ASTMC 309 Type II Class B

Coverage*:   4-6 Sq Mtr /Kg or Ltr. depending on the surface texture.

(* Coverage depends on site condition such as wind velocity, temperature, humidity and porosity of the surface.)

Note: The following surface treatment will have a perfect bonding over the surface coated with Hind Super Cure R.  Application of PVC, PVA, and Acrylic Co-polymers based emulsion paints. Fixing of Tiles with tile adhesive based on the polymers as mentioned above. Epoxy Resin, Polyurethane Resin, Poly-Sulphide Sealant system and bituminous emulsions coatings.

SHELF LIFE

12 months from the date of manufacturing in unopened conditions. To be stored in a cool and dry place away from direct sunlight.

PACKING 

Available in Industrial Packing (In Kg or Ltr.)

HANDLING PRECAUTION 

Hind Super Cure R is non-toxic but ingestion is to avoided. Any splashes to the skin must be washed with water. If contact with eyes occurs, wash well immediately with water and seek medical advice.